50 mm Circular Stop Face IEC Test Finger Probe
Compliance is verified by inspection, the test of Clause 21.1, and the application of a force not exceeding 5 N using a 50mm circular stop face test finger that is similar to Test Probe B of IEC 61032, but replaces the non‑circular stop face with a circular stop face with a diameter of 50 mm.The test probe shall be applied to appliances equipped with adjustable mechanisms—such as belt tensioning devices—with these mechanisms adjusted to the most unfavorable position within their travel range. Belts shall be removed if necessary.